Hardware configuration.
CNC 8070
CENTRAL UNIT FOR CABINET (Q7-A PLATFORM).
7.
Connections.
·161·
(REF: 1911)
7.8.5 Feedback connection.
The central unit has one feedback input. The feedback signals may be incremental (TTL,
differential TTL, Vpp).
Connector pinout.
Cable characteristics.
We recommend to run the feedback cables as far away as possible from the power cables
of the machine.
The cable being used must have overall shield. The cable shield must be connected to the
metallic hood at each end. The unshielded portion of the wires of an unshielded cable cannot
be longer than 75 mm.
Plug-in part. 15-pin male SUB-D HD type connector.
Connect the cable shield to the connector housing at both ends.
Pin. Incremental signal.
1A
2/A
3B
4/B
5I0
6 /I0
7AL
8/AL
9+5 V DC
10 +5 V DC
11 GND
12 GND
13 - - -
14 - - -
15 - - -
Fagor Automation offers a wide range of cables and extension cables to connect the feedback systems
to the CNC. The cable characteristics , as well as its length, depend on the type of feedback being
used. Refer to our catalog for further information.