10.4 Enclosure and mounting of the module.
10.4.1 Enclosure design.
The enclosure must meet the following requirements:
• Keep the enclosure clean. If the enclosure has ventilation holes, anti-dust filters should
be installed in all of them.
• Reserve some room for the laying out cables in the connector area. This space must allow
for the connection of cables, while accounting for their bending radius.
• The cabinet must consider the minimum recommended distances between the enclosure
walls and the hardware to let the air flow and improve heat dissipation.
Dimensions of the cut off part and the enclosure.
To meet the previous requirements, Fagor recommends the following.
• The enclosure must not have any ventilation holes, because they could let dust or other substances
in.
• To improve heat dissipation, install a fan inside the enclosure for air circulation.
Before building an enclosure with glass fiber u another poor heat dissipating material, contact Fagor
Automation.
mm inch
W 392 15.43
H 147 5.79
mm inch
D74 2.91
e 1.5 - 4 0.06 - 0.16