EasyManua.ls Logo

Fagor CNC 8070 - Actions (move sections and print graphics).

Fagor CNC 8070
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware configuration.
CNC 8070
11.
VERTICAL KEYB / VERTICAL KEYB+MOUSE.
Hardware functionalities.
·224·
(REF: 1911)
Keys of a passive monitor.
Connection of the keys of the LCD15 passive monitor. Maximum cable length is 1 meter.
24 V DC voltage supply.
CAN bus.
CAN bus. Address (node) of the element within the bus (0-15).
The "Address" switch also sets the priority of the node within the bus; the lower the number
the higher the priority. We recommend the keyboard and jog panel to be the last nodes of
the bus.
Connector data.
Number of poles. 3.
Pitch. 7.62 mm.
Connection technique. Screw connection.
Minimum/maximum tightening torque. 0.5 / 0.6 Nm.
Minimum/maximum section. 0.2 / 2.5 mm².
Minimum/maximum AWG section. 24 / 12.
Rated current In. 12 A.
Cable data.
Length to be stripped. 7 mm.
See "11.5 Power supply for the module." on page 222.
Connector data.
Number of poles. 5.
Pitch. 3.5 mm.
Connection technique. Screw connection.
Minimum/maximum tightening torque. 0.22 / 0.25 Nm.
Minimum/maximum section. 0.14 / 1.5 mm².
Minimum/maximum AWG section. 28 / 16.
Rated current In. 8 A.
Cable data.
Length to be stripped. 7 mm.
See "11.7 Bus CAN (CANfagor/CANopen protocols)." on page 226.
Each one of the elements integrated into the CAN bus is identified
by the 16-position rotary switch (0-15) "Address" (also referred to
as "Node_Select"). The CNC must always occupy position "0" and
the rest of the elements of the bus will occupy consecutive
positions starting with "1".
Plug-in part. 3-pole Phoenix-type combicon connector (7.62 mm
pitch).
Pin Signal. Function.
1Chassis.
2 GND 0 V reference signal.
3 +24 V Power supply.
1
Plug-in part. 5-pole Phoenix-contact minicombicon connector (3.5 mm
pitch).
Pin. Signal. Function.
1 GND Ground / 0 V.
2 CL (LOW) bus signal.
3 SH CAN shield.
4 CH (HIGH) bus signal.
5 SH CAN shield.

Table of Contents

Other manuals for Fagor CNC 8070

Related product manuals