Hardware configuration.
CNC 8070
13.
OP-PANEL / OP-PANEL+SPDL RATE.
Hardware functionalities.
·248·
(REF: 1911)
CAN bus. Address (node) of the element within the bus (0-15).
CAN bus. Line terminating resistor (·LT· selector).
RUN led. Module status.
ERR led. Transmission status.
Each one of the elements integrated into the CAN bus is
identified by the 16-position rotary switch (0-15) "Address"
(also referred to as "Node_Select"). The CNC must always
occupy position "0" and the rest of the elements of the bus will
occupy consecutive positions starting with "1".
The ·L switch identifies which are the elements that occupy
the ends of the CAN bus; that is, the first and last physical
element in the connection. The terminating elements must
have the resistor activated (position 1) but not the rest of the
elements (position 0).
Green Led. The meaning depends on the blinking frequency.
Blinking rate. Description.
Intermittent. Module in PRE-OPERATIONAL state.
Single blinking. Module in STOPPED state.
On. Module in OPERATIONAL state.
Red Led. The meaning depends on the blinking frequency.
Blinking rate. Description.
Off. The module is ready to run.
Intermittent. Module configuration stage.
Single blinking. Poor transmission. At least one of the error
counters of the CAN controller has reached
the alarm level.
Double blinking. There is no communication with the cpu.
On Error. The CAN controller is in "Bus Off"
state.

Table of Contents