Hardware configuration.
CNC 8070
16.
CNC-FPS. FAGOR-UPS (Q7-A PLATFORM ONLY).
Specifications.
·260·
(REF: 1911)
16.1 Specifications.
16.2 Dimensions.
Type. Description.
General. Uninterruptible Power Supply with integrated battery.
Dimensions (width x height x depth)
- 120.1 × 169.2 × 135.7 mm.
- 4.72" × 6.66" × 5.34".
Weight.
- 3,8 kg (8,3 lb).
Do not throw used batteries into the trash. The batteries must be
disposed of in accordance with the applicable national regulations.
Input data Rated input voltage: 24 V DC.
Input voltage margin: 18 V DC ~ 30 V DC.
Current absorption: 14 A.
Charge time: 24 hours.
Output data. Network operation.
Rated output voltage: 24 V DC.
Output voltage range: 18 V DC ~ 30 V DC (U
OUT
= U
BAT
- 0,5).
(depending on input voltage).
Rated output current: 10 A (permanent).
Power Boost: 15 A (permanent).
Output data. Battery operation.
Rated output voltage: 24 V DC.
Output voltage range: 19.2 V DC ~ 27.6 V DC.
(depending on battery voltage).
Rated output current: 10 A (permanent).
Power Boost: 15 A (permanent).
Time buffer (I
OUT
=I
N
): 180 min (1 A) / 10 min (10 A).
Ambient. Degree of pollution: 2.
Degree of protection: IP20
Protection class: Class III
Ambient temperature (service):
- Between 0 ºC (32 ºF) and 40 ºC (104 ºF).
Ambient temperature (storage/transport):
- Between -15 ºC (5 ºF) and 40 ºC (104 ºF).
Humidity at 25 ºC (5 ºF) non condensing:
- 95 %.
a
b
mm inch
a 120.1 4.72
b 169.2 6.66
c 135.7 5.34
c