EasyManua.ls Logo

Fagor CNC 8070 - 17.1 Install and configure the communication software at the CNC.

Fagor CNC 8070
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware configuration.
CNC 8070
INSTALLING AND CONFIGURING A THIN CLIENT (EPATEC
17.
Install and configure the communication software at the CNC.
·265·
(REF: 1911)
17.1 Install and configure the communication software at the CNC.
The central unit and the Thin Client communicate through a third-party remote desktop
software, in this case VNC. To install the VNC software, the CNC must be set in administrator
mode. Refer to the installation manual for further detail.
During installation, follow the instructions appearing on the screen and, if necessary, select
the following options.
1 Install only the "VNC Server" component.
2 Select the following configuration options. With this configuration, start the CNC up, the
VNC will remain waiting and its icon will appear in the notification area of the task bar
(next to the clock).
3 When installation is done, the program shows the following option tabs.
The access to the administrator mode is enabled with the validation code ("Open system" software
option). If you don't have this software option, (i.e. you have a "closed system") you will not be able
to access the administrator mode and, therefore, you will not be able to install third-party software.
If the CNC is not in administrator mode, the changes made to protected folders or files will be operative
until the unit is turned off and back on, the CNC will then restore the initial configuration. The changes
made to unprotected areas of the disk will remain.
i
on the "Security" tab, select "No Authentication".
On the "Connections" tab, select "Disconnect idle clients after
(seconds)" with 0 seconds.