Hardware configuration.
CNC 8070
5.
CENTRAL UNIT + MONITOR (ETX PLATFORM).
Power supply for the module.
·62·
(REF: 1911)
5.7.1 Voltage supply at 24 V DC.
Power the CNC with a 24 V DC ±10 % 3.5 A power supply.
Current peak of 90 A on power-up.
Connector pinout.
Consumption.
Consumption: 85 W (maximum).
5.7.2 Power supply with a Fagor battery.
Optionally, it is possible to connect an external Fagor battery to turn off the equipment in a
controlled manner during a power outage. The battery provides an autonomy of about 20
minutes when it is fully charged.
Connector pinout.
Plug-in part. 3-pole Phoenix-type combicon connector (7.62 mm
pitch). Rated current; 12 A.
Pin Signal. Function.
1Chassis.
2 GND 0 V reference signal.
3 +24 V Power supply.
1
Plug-in part. 5-pole Phoenix-contact minicombicon connector (3.5 mm
pitch). Rated current; 8 A.
Pin Signal. Function.
1 Vc- Recharging the battery through the central
unit.
2Vc+
3Chassis.
4 Vb+ Central unit powered by the battery.
5Vb-