Hardware configuration.
CNC 8070
CENTRAL UNIT + MONITOR (ETX PLATFORM).
5.
Hardware functionality. Connectors.
·75·
(REF: 1911)
5.8.6 Handwheel connector (only for C70-10K).
Connector X11. Handwheel connection.
10-pin male Phoenix minicombicon contact (3.5 mm pitch).
The C70-10K model admits the connection of up to 3 handwheels (MPG1, MPG2 and MPG3)
with A and B signals (5 V DC TTL). If he handwheel has an axis selector button, the button
signal may be connected to a digital input and may be managed from the PLC using the
NEXTMPGAXIS mark.
X11 Handwheel.
Handwheel connection.
Rear view.
Pin Signal Function
1 +5 V Power supply.
2- - -
3- - -
4 MPG3-B B signal of the third handwheel.
5 MPG3-A A signal of the third handwheel.
6 MPG2-B B signal of the second handwheel.
7 MPG2-A A signal of the second handwheel.
8 MPG1-B B signal of the first handwheel.
9 MPG1-A A signal of the first handwheel.
10 GND Power supply.
789345612 10
MPG2-B
MPG2-A
MPG1-B
MPG1-A
GND
MPG3-B
MPG3-A
5 V DC
Cable shields must be connected to the ground plate. See "5.12.5 Feedback connection." on page 87.