Loading...
Hardware configuration.
CNC 8070
5.
CENTRAL UNIT + MONITOR (ETX PLATFORM).
housing for the compact flash and battery-powered RAM memory.
·78·
(REF: 1911)
5.10 housing for the compact flash and battery-powered RAM memory.
The housing for the compact flash and the battery of the non-volatile RAM memory is located
on top of the central unit. The type of battery depends on the CNC model.
How to replace the battery of the non-volatile RAM memory (3Volt CR2450).
How to replace the battery of the non-volatile RAM memory (CN371).
1 Turn the CNC off and unplug it.
2 Get into the enclosure by removing the protective
cover.
3 Remove the battery by pulling it up smoothly.
4 Insert the new battery maintaining the same
polarity. The battery must get into its housing easily,
without having to force it.
5 Put the protective cover back on.
6 Plug the unit in.
While the battery is being replaced, the CNC keeps the
data of the non-volatile RAM memory.
1 Turn the CNC off and unplug it.
2 Get into the enclosure by removing the protective
cover.
3 Disconnect the battery from the CNC by pulling the
connector softly. Remove the battery from the lid.
4 Secure the battery on the lid and connect the battery
to the CNC respecting its polarity.
5 Put the protective cover back on.
6 Plug the unit in.
While the battery is being replaced, the CNC keeps the
data of the non-volatile RAM memory.
CF / battery
Battery
Compact
Flash
Compact
Flash
Battery

Table of Contents