"Logic analyzer" service
18.9.2 Save, load and reset the analyzer configuration
Save the configuration
This option is used to save the current configuration of the logic analyzer (PLC variables and
expressions, trigger conditions, graphic traces) into a file. When selecting this option, the
CNC shows a list of trace files (TRC) already saved. To save the current configuration:
1 Define the file name at the bottom window. To replace an existing file, select it from the list.
2 Press [ENTER] to save the configuration or [ESC] to return to the logic analyzer without
saving the configuration.
Load the configuration
This option is used to recover a logic analyzer configuration that has been stored earlier.
When selecting this option, the CNC shows a list of trace files (TRC) already saved. To load
one of these files:
1 Define the file name at the bottom window or select it from the list.
2 Press [ENTER] to save the configuration or [ESC] to return to the logic analyzer without
loading the configuration.
Initialize the configuration
This option is used to reset all the analyzer data eliminating the defined variables or
expressions as well as the trigger condition and trigger type. The traces are also deleted
because there are no variables to be analyzed.