EasyManua.ls Logo

Fagor CNC 8070 - -Monitoring- service

Fagor CNC 8070
414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating manual
CNC 8070
DDSSETUP
21.
(REF: 1505)
·387·
Monitoring– service
21.6 –Monitoring– service
List of variables of a Sercos drive.
List of variables of a Mechatrolink device.
Horizontal softkey menu.
Save, load or reset the list of variables to monitor.
Begin and end the monitoring of variables.
Edit the list of variables to monitor.
The variables to be monitored are defined from the command line; edit the name of the
variable and press the [INS] key. For Sercos, the softkey "Add" can also be used, it shows
a window for selecting the variables or parameters to monitor.
To delete a variable or parameter from the list, select it and press the [DEL] key. The entire
list may be deleted from the horizontal softkey menu.
Mechatrolink variables.
The range of available variables is MLINK0 to MLINKF and they will be associated with the
devices through their name (MLINK7.X) or through the node number (MLINK7.1). If the
variable does not indicate any device, the CNC associates with it the device active at the
This service monitors the parameters (Sercos and Mechatrolink) and the variables (Sercos)
of any drive. The user selects the variables to be monitored.
The command line is located at the bottom of the window. See "21.9 Command line." on
page 392.
Softkey. Function.
Save the list of variables to monitor.
This softkey saves the list of variables to monitor into a file (extension dwf).
Restore the list of variables to monitor.
This softkey restores the list of variables to monitor from a file.
Reset the list of variables to monitor.
This softkey deletes all the variables defined in the window.
Softkey. Function.
Begin monitoring.
End monitoring.