Operating manual
CNC 8070
DDSSETUP
21.
(REF: 1505)
·393·
Command line.
• Read and write parameters. To read a parameter, edit its name and press [ENTER]. To
write a parameter, assign a value to it and press [ENTER].
From the command line, it is possible to access any parameter of the device using its
identifier (hexadecimal number between P0000 and PFFFF).
• Obtain information on device status. Write the name of the command and press [ENTER].
• Insert variables in the monitoring window Access the monitoring service, edit the name
of the variable and press [ENTER].
P102 Read parameter P102.
P102 = 800 Write the value of 800 in parameter P102.
MSTATUS Device status.
MSUBSTAT Device substatus.
MALARM Warning or error code reported by the device.
MIOMON Status of the device inputs and outputs.