Loading...
CNC8070
R
EF
. 0402
E
RROR
SOLUTIONS
Page 121 of 128
Tool and tool
magazine table
TOOL AND TOOL MAGAZINE TABLE
‘The tool cannot be loaded into position %1’
DETECTION During the manual loading of a tool from this dialog box, from the magazine list or
loading the magazine table.
CAUSE The tool does not fit in that magazine position, it is already in the magazine or it is
not defined in the tool table.
SOLUTION Choose a big enough magazine position. Check that the tool is defined in the table.
‘The %1 tool cannot be unloaded’
DETECTION During the manual unloading of a tool from this dialog box, on the magazine list or
loading the tool table or the tool magazine table.
CAUSE The tool is not in the magazine.
SOLUTION Select a tool that is in the magazine.
‘The maneuver cannot be executed. Check that the spindle is empty’
DETECTION When executing a ground tool loading or unloading block.
CAUSE The spindle is not empty or there is a channel in error status.
SOLUTION Unload the tool from the spindle. Check that the status of all the channels is “READY”.
‘Wrong table type selected’
DETECTION When loading the tool table or magazine table.
CAUSE The file being loaded either does not correspond to the table to be loaded or has been
edited externally.
SOLUTION Choose the file corresponding to the table to be loaded.
'The tool does not exist or is already loaded into the magazine'
DETECTION When loading a tool into the magazine with or without maneuver.
CAUSE The tool does not exist or is already in the magazine, in the spindle or in the tool
changer arms (if any).
SOLUTION Define a tool. If it is in the spindle or in the tool changer arms, load it into the magazine.
‘Tool %1 cannot be eliminated’
DETECTION When deleting a tool or when loading the tool table.
CAUSE The tool cannot be found.
SOLUTION The tool is missing, therefore, cannot be eliminated. If it occurs when loading the table,
initialize the table with the softkey and load the table again.
'Tool %1 does not exist or is not loaded into the magazine'
DETECTION When unloading a tool from the magazine, when forcing the tool position or when
loading the magazine table.
CAUSE The tool does not exist or is not loaded into the magazine.
SOLUTION Define the tool and load it in the magazine.