CNC8070
R
EF
. 0402
E
RROR
SOLUTIONS
Page 15 of 128
Errors 1000-1999
1063 'Incompatible G functions (G108/G109/G193)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1064 'Incompatible G functions (G196/G197)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1065 'Incompatible G functions (G17/G18/G19/G20)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1066 'Incompatible G functions (G136/G137)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1067 'Incompatible G functions (G40/G41/G42)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1068 'Incompatible G functions (G151/G152)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1069 'Incompatible G functions (G54-G59/G159)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1070 'Incompatible G functions (G5/G7/G50/G60/G61)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1071 'Incompatible G functions (G70/G71)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1072 'Incompatible G functions (G80-G88/G160-G166/G281-G286/G287-G297)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1073 'Incompatible G functions (G90/G91)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.
1074 'Incompatible G functions (G93/G94/G95)'
DETECTION During execution.
CAUSE Two or more G functions of the same group cannot be programmed in the same block.
SOLUTION Program them in different blocks.