10.1 Error diagnosis
The errors and warnings are indicated in the thermometers display by the following codes:
Faulty boiler temperature probe (Not detected
or out of range [23ºF-392ºF]).
(E1 / BP) E1 / Boiler Probe
Faulty tank temperature probe (Not detected or
out of range [23ºF-392ºF]).
(E2 / TP) E2 / Tank Probe
Boiler overheating (>210ºF).
(E3 / BO) E3 / Boiler Overheating
Tank overheating(>197ºF).
(E4 / TO) E4 / Tank Overheating
Boiler heating failure.
(E5 / BH) E5 / Boiler Heating
Tank heating failure.
(E6 / TH) E6 / Tank Heating
Draining error. After 2 minutes with drain cycle
the level of the tank has not dropped
(E7 / DR) E7 / Drain
The boiler does not fill. After 8 minutes the
boiler is not full.
(E8 / BF) E8 / Boiler Filling
The tank does not fill.
(E9 / TF) E9 / Tank Filling
Rinse error. The boiler level does not decrease
during the rinse cycle.
(E10 / RS) E10 / Rinse
All errors disappear when switching off the machine, but the error could appear again if it is not corrected.
WARNINGS:
A cycle is trying to run with the
door open.
WARNING on display 3 times.
The door is open when filling
the machine.
WARNING on display 3 times every
minute until door is closed.