18
10 TIMER (M)
The cycle timer is comprised of 3 sections (M1 to M3). Each one has a 3 position micro switch (line
/normally closed /normally open) and 1 drive motor.
M1: This is the (ON) cycle micro, and stays activated throughout the completion of the cycle. The M1
line in (violet) wire comes from the press valve (P1) and feeds the (red ) normally closed position to
the start switch as well as the (pink ) to normally open position on (M-1) and line in to ( M2/ M3).
Also the cycle light and timer motor are fed via this line.
M2: Wash sequence micro. In this sector the (pink) line feed supplies the normally open position
(grey) line to selector position (#1 & #2). Pump motor (MBL) is energized upon activation of the
micro thru position (#1a) down to the motor. Drain pump (BD) is energized upon activation of the
micro thru position (#2a) down to the pump.
In the normally close position the (yellow) will feed press valve (P2) for drain.
M3: the rinse sequence micro. In this sector the (pink) line feed supplies the normally open (white)
position to the fill valve (V1). Upon activation the water valve is energized for 15 seconds of rinsing.
11 SELECTOR SWITCH (IG)
0 : When 0 setting is selected, all the contacts are open.
: When drainage setting is selected, contacts: 2-2a, 4-4a, 5-5a and 8-8a of the electrical
diagram are closed.
: When 120 seconds cycle is selected, contacts: 1-1a, 4-4a, 6-6a, 7-7a and 8-8a of the
electrical diagram are closed.
: When cold rinse setting is selected, contacts: 1-1a, 3-3a, 4-4a, 6-6a, 7-7a and 8-8a of the
electrical diagram are closed.