Power line connection
6.
POWER LINE CONNECTION
Choke
214
Ref.2003
· 210 ·
QC-PDS
HARDWARE
Electrical connection
F. H6/7
CHOKE RPS-160. Electrical installation.
- KM1 CONTACTOR
2x MPC-1x70
3 CONTACTS
+ AUXILIARY CONTACT
T1 T2 T3
2x MPC-1x70
2x MPC-1x70
2x MPC-1x70
2x MPC-1x70
2x MPC-1x70
USE 6x METAL CLAMPS.
NOT SUPPLIED BY FAGOR
CHASSIS SUPPORT
SHIELD
STRIP THE UNIPOLAR CABLES
BEFORE TO EXPOSE THE SHIELDS
SINGLE-POLE CABLES
2x70 mm² (Ø 9.5 mm) OR
1x150 mm² (Ø 13.8 mm)
PER PHASE
CHOKE RPS-160. TERMINALS T1-T2-T3
POWER INPUT FROM - KM1 CONTACTOR
CHOKE RPS-160. TERMINALS U1-V1-W1 FOR POWER OUTPUT
TO THE QC-RPS-160-XX POWER SUPPLY
TOP VIEW
QC-RPS-160-XX
U1/U V1/V W1/W
USE 6x TERMINALS FOR M10
DOWEL PIN. NOT SUPPLIED
BY FAGOR
USE 6x TERMINALS FOR M10
DOWEL PIN. NOT SUPPLIED
BY FAGOR
ALWAYS INSTALL THE UNIT INSIDE THE
ELECTRICAL CABINET AND FIXED TO THE
FLOOR
SHIELD
SHIELD
BACK OF CABINET
> 100 mm
> 100 mm
ALWAYS INSTALL THE UNIT INSIDE THE
ELECTRICAL CABINET AND FIXED TO
THE FLOOR
BACK OF CABINET
SINGLE-POLE CABLES
2x70 mm² (Ø 9.5 mm) OR
1x150 mm² (Ø 13.8 mm)
PER PHASE
TIGHTENING TORQUE:
10-20 N·m
M10 DOWEL TERMINALS
USE NUTS AND
WASHERS
SUPPLIED WITH
THE UNIT
TOP VIEW
POSSIBILITY OF SEALING
THE LIDS
POSSIBILITY OF SEALING
THE LIDS
TIGHTENING TORQUE:
10-20 N·m
M10 DOWEL
TERMINALS
USE NUTS AND
WASHERS
SUPPLIED WITH
THE UNIT