The Fame Audio Monitor SM-80A is an active monitor designed for professional audio applications, offering a blend of robust construction, essential features, and reliable performance. This device is optimized for use in various settings, including stage monitoring, studio applications, and general sound reinforcement where a compact yet powerful monitor is required.

Function Description:

The Fame Audio Monitor SM-80A serves as an active monitor, meaning it has a built-in amplifier, eliminating the need for an external power amplifier. This design simplifies setup and ensures optimal matching between the amplifier and the speaker components. Its primary function is to reproduce audio signals accurately, allowing musicians, sound engineers, and presenters to hear their sound clearly in real-time. The monitor features a combination input (XLR/6.35mm jack combo) for versatile connectivity, accommodating both balanced and unbalanced signals from various audio sources such as mixing consoles, instruments, or other playback devices. An XLR line out is also provided, enabling the signal to be daisy-chained to other monitors or audio equipment.

The device incorporates a main level adjust control, allowing users to fine-tune the output volume to suit their specific needs and environment. An overload LED indicates when the input signal is too high, helping users prevent distortion and potential damage to the speaker. The power mode switch offers options for "ON," "OFF," and "AUTO." In "AUTO" mode, the device turns to STANDBY after some minutes of no signal and automatically switches ON when a signal is detected, contributing to energy efficiency. A power switch (ON/OFF) provides direct control over the unit's power status. The monitor is equipped with a power connection seat/fuse, ensuring electrical safety and easy replacement of the fuse if necessary.

Important Technical Specifications:

  • Model: Fame Audio SM-80A
  • Type: 8" Monitor
  • Frequency Response: 80-19000Hz
  • Power Output: 70W
  • Max. SPL: 114 dB
  • Power Input: 220-240 V / 120 VA
  • Line In: XLR/6.35mm jack combo
  • Line Out: Sym. XLR
  • Dimensions (WxHxD): 280 x 263 x 317mm
  • Weight: 8 Kg

The 8-inch speaker size, combined with a 70W power output and a maximum SPL of 114 dB, indicates that the SM-80A is capable of delivering clear and sufficiently loud audio for its intended applications. The broad frequency response ensures that a wide range of audio frequencies, from bass to treble, are reproduced accurately. The compact dimensions and relatively low weight make it portable and easy to position in various setups.

Usage Features:

The Fame Audio Monitor SM-80A is designed for straightforward operation. Before switching on, all connections should be made using high-quality and undamaged cables. The input section supports both balanced (XLR) and unbalanced (6.35mm jack) signals, providing flexibility for different audio setups. For balanced connections, the XLR/6.35mm combo input uses pin 1 for shield/ground, pin 2 for hot/positive, and pin 3 for cold/negative. For unbalanced 6.35mm jack connections, the tip is hot/positive, and the sleeve is ground. For balanced 6.35mm jack connections, the tip is hot/positive, the ring is cold/negative, and the sleeve is ground.

The main level adjust knob (1) allows users to control the output volume. The overload LED (4) will light up if the input signal is too strong, indicating potential clipping. In such cases, the input level should be reduced at the source or via the main level adjust. The power mode switch (5) offers convenience and energy saving, especially in installations where the monitor might not be continuously used. The ON/OFF switch (6) provides a direct way to power the unit.

For installation, the device should be placed on a stable surface or mounted securely to prevent damage. Adequate ventilation is crucial to prevent overheating; therefore, the ventilation slots should not be covered. A minimum distance of 20 cm from walls or other structural objects is recommended. The device should not be exposed to direct rain, moisture, or liquids.

Maintenance Features:

Regular maintenance is essential to ensure the longevity and optimal performance of the Fame Audio Monitor SM-80A. The ventilation grilles should be cleaned regularly to remove dust and dirt, which can impede airflow and lead to overheating. The unit should be switched off and disconnected from the mains supply before cleaning. A lint-free, damp cloth can be used for cleaning; harsh solvents or alcohol should be avoided.

In case of a malfunction, the device should not be opened by unauthorized personnel. Repairs should only be carried out by qualified service personnel. Common troubleshooting steps include checking the network connection and fuse, verifying cable connections at inputs and outputs, and inspecting speaker or XLR cables for defects. If no sound is produced but the power LED lights up, defective cables or speakers might be the cause.

The fuse is a standard IEC127 type (5x20mm) and should only be replaced with a fuse of the correct rating (T 1.0 AL 250VAC). Using a short-circuited fuse or bridging the fuse holder is strictly forbidden.

Safety Instructions:

Several safety warnings are highlighted in the manual:

  • Electrical shock: The device contains high voltages. Do not open the housing. Repairs should only be performed by qualified personnel.
  • Short circuit: Modifications to the power cord or plug are prohibited. Use only the supplied power cord and ensure proper grounding.
  • Babies and children: Packaging materials should be kept out of reach of children. Small parts from the device could be swallowed.
  • Hearing damage: Professional speaker systems can produce harmful sound levels. Prolonged exposure to levels above 85 dBA SPL can cause permanent hearing damage. Always use hearing protection.
  • Overheating: The maximum permissible ambient temperature is 40°C. Ensure adequate ventilation and do not cover the ventilation slots.
  • Operating conditions: The device is suitable for indoor use only. Avoid direct rain, moisture, or liquids.
  • Power supply: Ensure the device voltage matches the local mains voltage. Use a residual current circuit breaker (FI).
  • Fuses: Replace fuses only with the specified type and rating.
  • Condensation: Allow the unit to adapt to ambient temperature before commissioning to avoid condensation.
  • Unwanted odours: A new product may sometimes produce temporary odours, which will dissipate after a few minutes.
  • Magnetic fields: Speakers can cause static magnetic fields. Maintain sufficient distance from equipment that may be affected.

Environmental Protection:

The manufacturer, MUSIC STORE professional GmbH, is committed to reducing packaging waste. Environmentally friendly and recyclable materials are used. Packaging components should be disposed of properly.

  • Disposal of packaging: Paper, plastic, and other materials should be separated and recycled according to local regulations.
  • Disposal of batteries: Batteries should not be disposed of in household waste but at official collection points or disposal stations.
  • Disposal of old device: This device is subject to the WEEE Directive (Waste Electrical and Electronic Equipment). It must not be disposed of with household waste but at an approved waste disposal company or local waste disposal office.

The Fame Audio Monitor SM-80A is a reliable and user-friendly active monitor, suitable for a range of professional audio applications, provided that all safety and usage guidelines are strictly followed.

Fame Audio SM-80A Specifications

General IconGeneral
BrandFame Audio
ModelSM-80A
CategorySpeakers
LanguageEnglish

Related product manuals