The switch on the front of the iM.60 allows for:
• Automatic regulation (AUT),
• manual closing/opening or
• off (0).
The manually operated selections work directly on the motor,
bypassing the intelligent module.
In order to operate the motor remotely and manually (for example, to disinfect), a 10kΩ potentiometer with a
switch can be connected. Once this has been turned on, the control value for the air inlet will be determined by
the position of this potentiometer (8kΩ = 1%, 0kΩ = 99%).
The remote setting potentiometer takes precedent over all automatic settings - so, also over emergency
settings.
This operating possibility works only if the motor's rotating switch is set to Automatic.
When disposing of the iM.60 please comply with all relevant requirements and regulations applicable in your
country.