5
fantech
A
B
Cleaning
DANGER: Electrical shock hazard. Disconnect power before cleaning.
Exterior Parts
Use a mild, non-abrasive soap and clean water solution to clean the metal cabinet, handles and
wheels. Wipe dry.
Air Filter
Remove lter. Wash in a mild soap and water. Rinse with clean water. Air dry before reinstalling.
Torn or ripped lters should be replaced with a new lter.
Fan Motor
Does not require lubrication.
Condenser and Evaporator Coils
1. Light cleaning (gure 3)
Remove the air lter and spray evaporator coil with water.
2. Heavy cleaning (gure 4)
Open upper door. Remove plastic cleanout by pushing the two locking tabs and lifting. Spray water
at coils. Replace the cleanout.
A qualied refrigeration technician must service all refrigerant leaks.
If power to the unit is disconnected or unit is turned off, allow 3 minutes before restarting
the dehumidier. This allows the internal pressures to equalize.
Storage
Single unit
It is best to cover the unit if extended storage periods are contemplated. Remove all water in
collection system.
Stacking two units
This dehumidier can be stacked two high.
An assembled unit weighs 39 kgs. Position on a level surface.
Personal injury hazard. Use two individuals to lift. Maximum stacking height: 2 units.