EasyManua.ls Logo

FAZER 777 - Page 6

FAZER 777
6 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
30
Telephone applications in the CONT and VOLT modes (touch CONT or VOLT)
All applications of the CONT and VOLT modes in 220V/380V electric installations and devices have their
equivalents in telephone installations and devices. With the CONT mode it is easy to check the continuity of
conduction in case of telephone set's elements (e.g. bells) and cables. Identification of wires in cable boxes
becomes just as easy. The VOLT mode allows, among other things, to quickly determine the line's
polarization.
31
High voltage detection in cables in the PHASE/DETECTION mode
High voltage cable in cars with spark ignition emit, during their operation, electric field related with generation
of high voltage. Due to Fazer's high-level sensitivity in the PHASE and DETECTION mode you can detect this
field without damaging insulation. Turn off the motor. Detach high voltage cables running to ignition plugs;
leave one cable. Turn the ignition ON. Start the starter and check if Fazer reacts with cracking sounds.
32
Testing of fuses, light bulbs, etc. The CONT mode
Touch one of the fuse's terminals with one hand. Touch the other terminal with the measurement pin. If a
fuse, light bulb, etc. are in working order, Fazer will react.