3. Drive functions
3−44
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Resetting identification
The identification data can be reset manually with
PNU 1192:03. See section 5.4.16.
The adaptation data is also reset here.
Recommendation:
After exchanging components or changing parameters, the
identification data should be reset before carrying out a new
identification run.
Adaptation
After successful identification, the adaptation values are
automatically determined during operation.
Adaptation is able to independently improve non−optimal
control behaviour. The reason for poor control behaviour in
small tolerance windows are long−term effects and impre
cisely identified values.
Deactivating adaptation
Adaptation can be deactivated via the parametrisation. That
usually isn’t required in any configuration. Only
in extremely
rare cases does adaptation lead to worsened positioning be
haviour.
Important: Not every deterioration in the positioning behav
iour is due to faulty adaptation. Wear or weak construction
can also lead to the positioning times gradually being pro
longed, for example, or even the number of E30 messages
piling up. For this
reason, one should only deactivate adapta
tion if this is justified.

Table of Contents

Other manuals for Festo CPX-CMAX-C1-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-CMAX-C1-1 and is the answer not in the manual?

Festo CPX-CMAX-C1-1 Specifications

General IconGeneral
BrandFesto
ModelCPX-CMAX-C1-1
CategoryController
LanguageEnglish

Related product manuals