3. Drive functions
3−15
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Enable drive
CCON.ENABLE
Output Pin 2
1
0
Start
CPOS.START
Stop
CCON.STOP
1
0
1
0
1
0
1
0
1
0
24V
0V
Release brake
CCON.BRAKE
Operation enabled
CCON.OPEN
Drive enabled
SCON.ENABLED
Brake status
50 ms
open
closed
Fig.3/3: Open brake" sequence
An overview of different cases for setting and releasing the
brake is shown in Tab.3/3.
An overview of different cases for for activating and deactivat
ing the controller is shown in Tab.3/4.