Festo — MS6(N)-SV-...-E-10V24 — 2021-11e
Runtime performance
t1 > 5 ms: Level of EN2/EN1 must be HIGH for min. 5 ms (debounce time/input filter/stabi-
lisation time).
t2 < = 75 ms: maximum permissible delay time between EN1 and EN2. If exceeded, the product
is not pressurised and an error message is output.
t3 > = 15 ms: Level of EN2/EN1 must be LOW for min. 15 ms (debounce time/input filter/stabi-
lisation time).
t4 = 2 ms: maximum internal time delay caused by the program sequence.
tp1 } 2: Pressurisation > 300 ms
tp2 } 3: Exhausting > 1 s
Tab. 14: Runtime performance