Ill
-
1914
Section
No.
100.01
Page
25
Power
Plant
Mounts
POWER
PLANT
REMOVAL
Disconnect
battery
cables
(in
front
luggage
com-
partment).
Loosen
fuel
cap.
Drain
cooling
system.
Remove
cap
(4)
from
expansion
tank.
Disconnect
hose
(3)
from
air
injection
valve.
Discon-
nect
hose
(1)
from
air
cleaner.
Loosen
clamp
holding
fresh
air
duct
(5)
to
fan.
Remove
3
nuts
(2)
and
washers
holding
cover
on
air
cleaner.
Remove
4
nuts
holding
air
cleaner
on
carburetor.
Remove
not
holding
bracket
on
air
cleaner
to
engine.
Disconnect
hose
from
bottom
of
air
cleaner.
Remove
air
cleaner
with
fresh
air
duct.
1.
Hose.
2.
Nuts.
3.
Hose.
4.
Cap.
5.
Fresh
air
duct.
Disconnect
hose
(1)
between
air
pump
(2)
and
filter.
Disconnect
hose
(3)
from
air
pump.
Separate
heater
return
hose
(5)
at
coupling
joint
(4).
Disconnect
heater
hose
from
pump.
Disconnect
wires
from
alternator.
Remove
2
bolts
holding
louvered
protection
panel
below
carbon
trap
in
rear
firewall.
1
Hose.
2.
Air
pump.
3.
Hose.
4.
Coupling.
5.
Heater
Hose.
Disconnect
choke
linkage
(2)
from
carburetor.
Disconnect
hoses
(l
and
5)
from
carburetor
base.
Disconnect
Wires
(3)
from
carburetor.
Disconnect
vent
hose
(4)
from
carburetor.
Disconnect
wires
from
coil
to
distributor
at
distributor.
Disconnect
wires
from
oil
pressure
and
water
temper—
ature
sending
units.
Disconnect
wires
from
starter.
1.
Hose.
2.
Choke
linkage.
3.
Wires.
4.
Vent
hose.
5.
Hose.

Table of Contents