STEP 4. Manual self-test.
The Fibaro Smoke Sensor can automatically detect a malfunction. If malfunction is detected
an intermittent sound signal will start and alarm will be sent to the main Z-Wave controller.
Self-test may also be triggered automatically. Please, follow:
-make sure the battery is in place;
-press and hold B-button until the visual indicator glows white and short alarm sounds. After
3 seconds from the first beep smoke chamber operation will be checked.
Triggering fire alarm and beep mean positive result and should occur within 10 seconds.
Trouble signal or no fire alarm mean that the sensor is malfunctioning.
STEP 5. Contact with service.
If only one of steps above has failed, please contact with Fibaro Servicedesk at:
servicedesk@fibaro.com

Other manuals for FIBARO Smoke Sensor

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FIBARO Smoke Sensor and is the answer not in the manual?

FIBARO Smoke Sensor Specifications

General IconGeneral
Sensor TypePhotoelectric
Battery TypeCR123A
Wireless TechnologyZ-Wave
Operating Temperature0°C to 55°C
Dimensions65 x 28 mm
Alarm Sound Level85 dB
Radio Frequency868.4 MHz (EU) / 908.4 MHz (US)
Humidity Range0% to 93% (non-condensing)
RangeUp to 50 meters outdoors
SensitivityEN 14604:2005
CertificationsEN 14604