Operational problems
Blackened glass
The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture level not
exceeding 20% RH.
Insufcient intake of air from the top air control. Open the top air control further. The air shield system is more efcient
the more air is allowed to run over the glass panel.
The stove is run at too low a temperature.
Smoke in the room when opening door
Never open the door when there are high ames on the wood.
Poor chimney performance - consult chimney sweep.
Check the position of any tted ue damper or stabiliser and make sure it is in the open position.
Uncontrollable combustion
Damaged door seal. Fit new seal.
If there is an excessive chimney draft - t a draft stabiliser in the ue pipe - consult a chimney sweep.