11. For electric start only - Flip the engine switch to the START (ll) position for a few seconds and
then release.
12. For electric start only - Move the choke lever to the RUN position.
3sec.
13. Allow portable generator to run at no load for a few minutes to stabilize before plugging in
any electrical devices.
NOTICE If engine starts but fails to run, or if portable generator shuts down during operation,
check oil level. See Low Oil Shutdown section for more information.
NOTICE Observing frost on LPG cylinder and regulator is common during operation and normally
is not an indication of a problem. In unusual situations this frost may eventually restrict the flow of
LPG gas to the generator resulting in deteriorating performance. In these rare situations it can be
helpful to:
20
OPERATION
Exchanging fuel cylinders to allow the first cylinder to warm up, repeating as necessary.
Placing the LPG cylinder at the end of the generator near the handle, where engine fan
air flows out from the generator. This air is slightly heated by air flowing over the engine.
Do not place the LPG cylinder in the path of the muffler exhaust outlet.
The LPG cylinder and components can be temporarily warmed by pouring warm water over
them.