- 25 -
TEMPERATURE MEASUREMENT
With the ED56 it is possible to display the
temperatures the exhaust and ambient
sensors are measuring. The temperature of
each sensor can be displayed using the
following procedure:
Start the dryer as per normal operation, i.e.
1. Press POWER button.
2. Press START/PAUSE button.
- Dryer will now be operating normally.
3. Press & hold LOCK then press
< DRYNESS button at the same time.
The display will now change to display the
temperature of the exhaust sensor. The
temperature is displayed in c coded form
(see Reading Temperature Display).
4. Press < DRYNESS button again.
- The display will now show the
temperature of the Ambient sensor, again
this is in coded form.
5. Press > DRYNESS button to change the
display back to showing the exhaust
sensor temperature.
6. When either of the two dryness buttons
are pressed either the ambient or exhaust
sensor temperature will be displayed.
7. Press POWER button to return to normal
operation.
NOTE: Throughout the temperature reading
mode the dryer will continue as normal.