70
User Warnings
For a user warning, the dryer will either pause, or “limp on”, and flash an L.E.D at the
same time as sounding a user warning (the same sound AeroSmart™ makes when it is
plugged into the wall).
User Warning 6
Reason: The door is unable to close due to either clothes catching or an excessive
closing load.
Background: The mechanical teeth of the door closing mechanism are designed so
that any fabric hanging out the door will prohibit the closing mechanism
operating and the motor will stall. The sensor module will initiate the
drum to reopen then attempt to close the door again. After the third
failed attempt the Dryer will pause, the “user warning” sound. Pressing
Start or Power will reset the warning.
It is also possible that a very heavy clothes load is positioned in the
drum so that the motor is unable to lift the load. If this is the case, the
user should either reposition the load or remove some of the load.
If either of the reasons stated above is not evident, it may be that there
is some other reason the dryer closing mechanism is binding. If so, fix
the source of the problem.
Remedy: (1) Remove the obstruction.
(2) Reposition or remove some of the load.
(3) Fix the cause of binding in the door closing mechanism.
(4) Replace the motor control module.
(5) Replace the motor.
User Warning 30
Reason: Lid lock failed to lock. “I can’t lock the lid”
Background: When the user starts the dryer, multiple attempts are made to lock the
lid, and with each attempt the lid lock display on the control panel is
turned on. If the lid lock fails to operate, the dryer will return to the
“paused” mode, the user warning will sound. The lid lock failure warning
is retained as a “last fault” that may be retrieved in diagnostics mode,
but is not a normal fault display.
Remedy: (1) Close the lid.
(2) Replace the lid lock harness.
(3) Replace the lid lock.
(3) Replace the sensor module.