6 FAULT FINDING
6.1 Fault Finding
Fault Cause Repair
No operation. No power to unit.
No power at terminal C on
timer.
Hi-limit thermostat open circuit
(electric only).
Start button not operating.
Idler switch open circuit.
Motor seized or open circuit.
Door switch open circuit.
Resupply power to the unit.
Replace timer.
Replace hi- limit thermostat &
check for possible overheating
issues (see overheating).
Replace selector switch
assembly.
Check belt condition & replace if
necessary.
Check idler arm or pulley &
replace if necessary.
Check idler switch operation and
replace if necessary.
Check motor spins freely and
check windings. Replace if
necessary.
Replace door switch.
No heat. Selector set on No Heat/Fluff.
No power to terminal A on the
timer.
No motor operation.
No Power from Terminal 16
on the selector.
The safety, inlet, or drum
outlet thermostat failure.
The elements are open circuit
(electric model only).
No gas valve operation (gas
model only).
Open circuit motor switch.
Reset selector.
Replace the timer.
See No Operation section.
Replace the selector.
Check thermostats for continuity
and resistance of the resistors.
Replace if necessary.
Replace elements.
Check flame failure operation.
Check gas coil continuity.
Change gas valve assembly.
Replace the motor.