4. Install the dryer on a stable and level floor.
Free Standing Venting Options
The vent system should be less than
two metres long with no more than three 90⁰
bends.
Before a rear venting option is installed the dryer must be changed
from the front venting factory setup. Remove the outlet grille from the
front left-hand side and replace with the outlet cover from the rear left-
hand side. These covers should be gently pried at the sides to
prevent damage.
External venting with kit part number
PD-DK4W
External Venting
The dryer is vented with a kit that can be positioned to remove air to
the side.
The dryer is vented directly through the wall using a ducting kit in
combination with the duct adaptor supplied with the dryer.
The dryer is vented through a window using a ducting kit in
combination with the duct adaptor supplied with the dryer. This
requires the dryer to be a minimum distance of 140mm from the wall
to ensure the ducting is not restricted with tight bends or can be
crushed.
External venting with kit part number
PD-SVHCW4