427939
20
8.3 Exhaust Sensor Shorted to Cabinet
Code: 1010
Action: Unplug the exhaust sensor harness at the control module and check for continuity
between each of the sensor wires and the dryer cabinet. There should be no connection between
the wires and the cabinet.
If there is a short, replace the exhaust sensor and harness
8.4 Faulty Exhaust or Ambient Sensor
Code: 0110
Cause: The sensors are either open circuit or shorted.
Action: Unplug the exhaust sensor harness at the control module and check the resistance of the
sensor. (Refer to Testing the Exhaust Sensor). If faulty, replace it. If
the ambient sensor is
faulty, the electronic module will have to be replaced.
8.5 Over Temperature
Code: 1101
Cause: If the exhaust air temperature is above 90
o
C a fault code is given as the dryer
should not reach this temperature under normal operating conditions.
Action: Check the lint filter and exhaust duct for any blockage or restriction to the airflow.