599735A
36
F3 Water temperature measurement exceeds 85 degrees Celsius
The water temperature is sensed at greater than 85 degrees C / 185 degrees F.
The product will abort the wash program, log the fault, report to the user, and disable the power
supply.
Note: The isolation relay will be disabled. Power to the product will need to be disconnected
then reconnected for it to become fully functional again.
PRIMARY ACTION
Check the incoming water temperature is not too hot.
Check the temperature reading in diagnostics, and if 199, ensure the power connector is
properly fitted to the controller and the connector on the heater plate is correctly fitted.
SECONDARY ACTION
Check the resistance between pins 1 and 2 of the controller power connector is about 10K
at approximately 25
O
C / 77
O
F ambient room temperature.
If not (provided the harnesses are ok and the connectors are correctly fitted), replace the
heater plate (bad temperature sensor).
TERTIARY ACTION
Check that the temperature reading in diagnostics is the same as the temperature of the
water in the tub. If the tub water temperature is obviously below 85
O
C / 185
O
F, replace the
controller.
F4 Element has been on too long (about 4 hours) and water has not
reached required temperature
The element has been on too long (about 3 hours) and the water has not reached the required
temperature.
The product will abort the wash program, log the fault and report to the user.
PRIMARY ACTION
Check that the controller power connector and the heater plate connectors are properly
fitted and the harness is not damaged.
Check the resistance between pins 1 and 2 of heater plate PCB, and if open circuit, replace
the heater plate.
SECONDARY ACTION
Check the resistance between pins 1 and 2 of the controller power connector is about 10K
at approximately 25
O
C / 77
O
C ambient room temperature.
If not (provided the harnesses are OK and the connectors are correctly fitted), replace the
heater plate (bad temperature sensor).
TERTIARY ACTION
Replace the controller.
F5 Lid motor current(s) too high during start
Lid actuator is jammed up or down.
The product will abort the wash program, log the fault and report to the user.
PRIMARY ACTION
Check for dishes, cutlery or cups and glasses preventing lid from closing.
Check the lid actuators in diagnostics.
Check the yokes are moving freely and are not jammed at the front or the rear (physical
inspection).
SECONDARY ACTION
Replace the lid actuators.
TERTIARY ACTION
Replace the controller.