EasyManua.ls Logo

Fisher & Paykel RF175W - Refrigeration System Faults; Temperatures Are; Yes

Fisher & Paykel RF175W
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
321037
100
Are the
compartment
temperatures
set correctly?
Wait until
refrigerator
completes defrost
cycle.
Adjust settings.
Advise customer
product OK.
Check
temperatures.
Check compressor
and system for
leaks/blockage and
repair as required.
Yes
Yes
No
No
No
Remove FC cover.
Is there a full frost
pattern on the
eva
p
orator?
Yes
Should the
compressor be
running? (Check
defrost and cycle
temperatures)
Is there power to
the compressor?
Refer Section
14.1
Repair as required.
No
Yes
17.14 Refrigeration System Faults

Table of Contents