5.4.6 Compressor Compartment Layout
The diagram below will assist in identifying the various pipes within the compressor compartment.
It should be read in conjunction with the full system diagram (See Diagram
5.3).
Diagram
5.4.6
1. Service tube (process pipe).
2. Suction line.
3. Discharge line into condenser.
4. Condenser to mullion.
5. Mullion to filter.
6. Capillary tube.
7. Filter dryer.
8. Filter process pipe.
5.5 FC Mullion Heater
The mullion heater is part of the condenser copper tubing (mullion heater) providing heat to the
gasket area of the FC compartment, preventing sweating of the gasket around the freezer
compartment.
5.6 Provision Compartment Duct
The duct covers provide an air passage up the rear wall of the provision compartment for the cold
air drawn from the evaporator by means of the PC fan located at the bottom of the duct in the
divider partition (refer to Diagram
5.6).
The duct channel uses moulded polystyrene duct for this purpose
8
2
3
7
6
1
4
5