8 DIAGNOSTIC MODES
To enter diagnostic modes, press and hold the MENU key, then press the UP key for 4 seconds.
The PC sensor temperature will be displayed on the LCD as shown in Diagram A. The actual
temperature of the PC is shown.
Please NOTE all temperatures shown on display are in degrees Celsius.
PC Sensor Temperature
Note: 4.0 shown on display, indicates the temperature of the pc sensor is 4.0
O
C (39.2
O
F).
Diagram A
PC Sensor Temperature
FC Sensor Temperature
Press the UP key once more – FC sensor temperature.
Note: 12.0 min shown indicates the temperature of the FC sensor is –12
O
C (10.4
O
F).
Diagram B
FC Sensor Temperature
Defrost Sensor Temperature
Press the UP key once more – Defrost sensor temperature.
Note: 18.0 min shown indicates the temperature of the Defrost sensor is –18
O
C (0.4
O
F).
Diagram C
Defrost Sensor Temperature