16 SERVICE REFERENCE
PROBLEM POSSIBLE CAUSES WHAT TO DO
PC Too Cold.
Cold Crispers. Ambient heater open
circuit.
Check I/O Fault Log.
Check continuity of element using multimeter.
Ice In Crispers. PC fan fitted upside
down.
Fan hub with label on to be facing PC.
PC fan not going.
Check I/O Fault Log.
Check voltage to plug, check wiring polarity.
Air leakage base duct
cover.
Seal with foam tape on duct divider spigot.
PC sensor location.
Remove insulation pad.
Cold
Compartment
Warm Top.
PC fan not going.
Check I/O Fault Log.
Check for mechanical obstruction.
Check power to plug.
Check polarity.
Replace fan.
Check for broken wires.
Total
Compartment
Too Cold.
FC fan not going.
Check I/O Fault Log.
Check power to plug.
Check for broken wires.
Check polarity.
Replace fan.
Short of gas.
Check run percentage, if high check
evaporator.
Check fully flooded evaporator, check for leak.
PC sensor inaccurate.
Check calibration of sensor ice point using
interface binary or refer to thermistor
resistance table in service manual.
PC Too Warm.
Warm
Compartment
Cool Bottom.
PC fan not going.
Check I/O Fault Log.
Check power to plug.
Check polarity.
Check for broken wires.
Replace fan.
Check fan is not jammed with ice or anything
else.
PC fan upside down.
Fan hub with label on to be facing PC. Refit.
Return duct iced up.
De-ice duct area behind chassis.
Check PC duct insulation for good seal in
return duct.
Check doors are sealing.