819091D
36
Fault Code 4
Reason: The resistance of all the temperature sensors are outside the normal range. (< 660
Ohms)
Primary Action: Check the 6-way RAST connector at the power module.
Secondary Action: Re-terminate the 6-way RAST connector.
Tertiary Action: Replace the power module.
Fault Code 5
Reason: The resistance of the FC sensor is outside the normal range (> 45K Ohms).
Primary Action: Check the sensor connection at the power module.
Secondary Action: Replace the sensor.
Fault Code 6
Reason: The resistance of the FC sensor is outside the normal range (<660 Ohms).
Primary Action: Check the sensor connection at the power module.
Secondary Action: Replace the sensor.
Fault Code 7
Reason: The resistance of the Evaporator sensor is outside the normal range (> 45K Ohms).
Primary Action: Check the sensor connection at the power module.
Secondary Action: Replace the sensor.
Fault Code 8
Reason: The resistance of the Evaporator sensor is outside the normal range (<660 Ohms)
Primary Action: Check the sensor connection at the power module.
Secondary Action: Replace the sensor.
Fault Code 9
Reason: The resistance of the PC sensor is outside the normal range (> 45K Ohms).
Primary Action: Check the sensor connection at the power module.
Secondary Action: Replace the sensor.
Fault Code 10
Reason: The resistance of the PC sensor is outside the normal range (< 660 Ohms).
Primary Action: Check the sensor connection at the power module.
Secondary Action: Replace the sensor.
Fault Code 11
Reason: The current measured for the ambient heater, PC fan and FC fan is lower than
expected.
Primary Action: Check the 6-way fan/LAH RAST connector at the power module.
Secondary Action: Re-terminate the 6-way fan/LAH RAST connector.
Tertiary Action: Replace control module.
Fault Code 12
Reason: The current measured for the ambient heater, PC fan and FC fan is higher than
expected.
Primary Action: Check the 6-way fan/LAH RAST connector at the power module.
Secondary Action: Re-terminate the 6-way fan/LAH RAST connector.
Tertiary Action: Replace the control module.
Fault Code 13
Reason: The low ambient heater is drawing less current than expected. Either the heater or
wiring is open circuit or the heater is faulty.
Primary Action: Check the wiring and connections at both the heater and the power module.
Secondary Action: Check the low ambient heater resistance. If not within limits, replace.
Fault Code 14
Reason: The low ambient heater is drawing more current than expected. Either there is a
short in the heater, or the heater is faulty.
Primary Action: Check the wiring and connections at both the heater and the power module.
Secondary Action: Check the low ambient heater resistance. If not within limits, replace.