15
DOOR CLEARANCES
D
A
B
WALL
WALLWALL
C
FF F FF F
GG G GG GG G
E
HINGE TO HINGE
Both doors open at the same time
- requires space between models
HINGE TO HINGE
Only allows a single door open at a time
INDICATES CAVITY CLEARANCES
INDICATES PRODUCT DATUM
CLEARANCES CONFIGURATIONS
DUAL INSTALL
TRIPLE INSTALL
RS2474S3RH1 Refrigerator with Stainless Steel Panels RD2474R, Handle Kit
AHD5RDS74 and Stainless Steel Toe Kick Panel AKRS2304
Left hand hinge is a mirrored version of the image shown. Left hand hinge can be
achieved using supplied parts.
RS2474FLJ1 Freezer with Stainless Steel Panels RD2474L, Handle Kit AHD5RDS74 &
Stainless Steel Toe Kick Panel AKRS204
Clearance Dimensions
in
mm
a Depth of door (90° open, measured from front of cabinetry)
2 5/8
600
B Minimum door clearance to adjacent wall (90° – reduced
internal access)* **
 1/8
80
C Minimum door clearance to adjacent wall (115° – full
internal access)* **
10 /4
27
D Minimum cabinetry clearance from side of door panel to
adjacent wall (non hinge side)
5/2
4
E Minimum clearance between products when opening hinge
to hinge. Allowing both doors to open at the same time**
4
100
Minimum Door Clearance (Vertical Gap)
in
mm
F Dual Install:
Stainless steel door panels (gaps equalized
during installation)
/16
5
Custom panels (width of custom panel increased to
maintain 4mm gap across multiple products)***
5/2
4
G Triple Install:
Stainless steel door panels (gaps equalized
during installation)
1/4
6
Custom panels (width of custom panel increased to
maintain 4mm gap across multiple products)***
5/2
4
* Use hinge limiting pin to restrict door opening to 90° where necessary
** Minimum dimensions shown are for the contemporary handle kit AHD5RDSF.
Custom panel and handle details need to be taken into account.
*** Refer to Custom Panel Dimensions and Multiple Install pages for further details.