Electrical connection should be located in an adjacent cabinet to either side oftheappliance or above
the appliance cavity. We recommend to use an isolating switch that is easily accessible to the user
aftertheappliance is installed.
WARNING!
z
Electrical shock hazard. Assume all parts are live.
z
Disconnect supply before servicing and installation.
ELECTRICAL AND PLUMBING CONNECTIONS
1 Recommended location for connections in adjacent area or unit
2 Alternative location for connections above the cavity
3 Alternative location for connections at rear of cavity
RS80 RS90
ELECTRICAL AND PLUMBING DIMENSIONS
MM MM
A Overall height of supply area 130 130
B Overall width of supply area 275 355
C Distance from left side of cavity 145 145
D Distance from the floor 72 72
Note: Dimensions are based on minimum depth of cavity.
Do not locate water or electricity in this area, keep clear of connections.
!
CAUTION: Central area can only fit water outlet and electrical plug if they are placed within a recessed cavity.
* In this location the water tap needs to be recessed into the wall, the recess must allow for an 80mm bend radius for the
watertube.
ELECTRICAL AND PLUMBING
Left side
of cavity
Floor
!
C b
A
Optional electrical
and water connection
location*
Electrical and water connections must be within this space if located
behind the appliance and must not protrude from the back wall.
100mm
100mm
d
1
1
3
2
17