Fault Code 4 Invalid Option Link Read.
The motor control module heat source option link read is invalid.
Remedy: Replace the motor control module. (Refer to Section 6.35)
Fault Code 6 Door Jammed - User Warning.
The door is unable to close due to either clothes catching or an excessive closing
load.
Remedy: (1) Remove the obstruction.
(2) Reposition or remove some of the load.
(3) Fix the cause of binding in the door closing mechanism.
(4) Replace the motor.
Fault Code 7 Motor Current Excessive.
Remedy: (1) Free up the dryer. Remove overload or cause of jamming.
(2) Replace the motor control module. (Refer to Section 6.35)
(3) Replace the motor. (Refer to Section 6.32)