479646
33
13 FAULT CODES
Before replacing any components always check the harness and connections.
Door is detected as not closed.
The door has been detected as not being closed
20 seconds after the program has been started.
(Refer to Err door open flow chart)
Expected water level not attained
within 8 minutes.
(Refer to Err no tAP flow chart)
The initial speed of the motor has been detected
as being out of sync. (Refer to Err 7:00 flow
chart)
The motor control module has been unable to start
the motor. (Refer to Err 7:01 flow chart)
The motor control module has detected a loss of
one of the phases of the motor. (Refer to Err
7:02 flow chart)
The motor control module has detected excessive
current. (Refer to Err 7:03 flow chart)
Motor Current Sense Error.
Motor current sensing circuit is faulty. (Refer to
Err 7:04 flow chart)
The supply voltage level has become too low to
power the motor control module. (Refer to Err
7:06 flow chart)
The motor control module has detected the motor
windings over temperature. (Refer to Err 7:07
flow chart)
The motor control module has detected that the
motor bridge electronics is over temperature.
(Refer to Err 7:08 flow chart)
M/C Module Self Test Error.
The motor control module during its self-test
routine has detected an error. (Refer to Err 7:09
flow chart)
Heater NTC error which is
displayed at end of program.
The heater NTC has malfunctioned.
(Refer to Err 10 flow chart)
Water level has exceeded flood
protection level.
Water level readings found to be above the flood
protection level. (Refer to Err 12 flow Chart)
The water level has not changed in 6 minutes.
(Refer to Err 37 flow chart)
Pressure sensor out of range.
Pressure sensor frequency is out of range. (Refer
to Err 74 flow chart)
The water failed to reach the selected wash
temperature. (Refer to Err 75 flow chart)
(Refer to Err 105 flow chart)
(Refer to Err 235 flow chart)
Run machine through rinse / spin cycle.