13.1 Fault Code Flow Charts
13.1.1 Door Open
Push the door to ensure door is
properly closed.
Turn the power off and then turn it
on again. Check there is 220-240v
AC between the Brown & Blue wires
of the door lock pins 2 & 3?
Check the door lock is correctly
connected if correct, replace the
door lock assembly.
Check the harness connecting the
door lock to the display module for
continuity.
Check that there is 220-240v AC
between connector CN1-1 and
CN2-1 at the PCB.
Replace display module.
N
Y
Close the door.
Repair the connection.