Do you have a question about the Fisher-Price myAIRVO 2 and is the answer not in the manual?
Brand | Fisher-Price |
---|---|
Model | myAIRVO 2 |
Category | Medical Equipment |
Language | English |
Lists all items included with the myAIRVO 2 humidifier.
Overview of the myAIRVO 2 unit and its associated accessories.
Instructions for unpacking the myAIRVO 2 unit from its packaging.
Steps for connecting the power cord to the myAIRVO 2 for different models.
Guidance on attaching the oxygen inlet extension kit.
Instructions for connecting the water chamber and heated breathing tube.
Procedure for powering on the myAIRVO 2 unit.
Description of the unit's warm-up phase and symbol.
Indicates the system is ready for patient use and its symbol.
Instructions for turning off the unit and entering drying mode.
Accessing and changing advanced device settings, for technical personnel.
How to change the operating mode between AIRVO 2 and myAIRVO 2.
How to set the language for the AIRVO 2 / myAIRVO 2 interface.
Sets the lowest target dew-point temperature for operator selection.
Sets the lowest target flow rate for operator selection.
Sets the highest target flow rate for operator selection.
Sets the highest oxygen fraction the operator can select.
Sets the lowest oxygen fraction the operator can select.
Option to enable or disable Junior Mode on the myAIRVO 2.
Defines the dew-point temperature setting specific to Junior Mode.
Sets the minimum flow rate for operator selection in Junior Mode.
Sets the maximum flow rate for operator selection in Junior Mode.
Sets the max oxygen fraction for operator selection in Junior Mode.
Sets the minimum oxygen fraction for operator selection in Junior Mode.
Procedure to test the heater plate functionality of the myAIRVO 2.
Test to verify the integrity of the system and detect leaks.
Test to identify blockages in the breathing circuit.
Test to verify the heated breathing tube connection.
Details electrical safety tests required for the myAIRVO 2.
Lists available spare parts for the myAIRVO 2.
Refers to user manual for storage and disposal instructions.
Declaration on electromagnetic emissions from the device.
Declaration on electromagnetic immunity of the device.
Guidance on separation distances for RF communications equipment.
Table for recommended separation distances based on transmitter power.
Visual representation of the user interface flow for environment settings.
Visual representation of the user interface flow for patient settings.
Information about the filter timer and its reset.
Troubleshooting steps for motor-related errors.
Troubleshooting for errors related to the heated breathing tube.
Troubleshooting for errors associated with the disinfection tube.
Troubleshooting steps for issues related to the water chamber.
Steps to resolve internal error codes on the myAIRVO 2.
Troubleshooting for flow-related errors.
Troubleshooting for temperature-related errors.
Steps to address brownout or power interruption errors.
Troubleshooting for issues with the oxygen sensor.
Details for the main manufacturer, Fisher & Paykel Healthcare Ltd.
Contact details for the Australian representative.
Contact details for the Spanish representative.
Contact details for the Swedish representative.
Contact details for the Swiss representative.
Contact details for the Taiwan representative.
Contact details for the Turkish representative.
Contact details for the UK representative.
Contact details for the USA and Canada representatives.