EasyManua.ls Logo

Fisher Scientific A-200DS User Manual

Fisher Scientific A-200DS
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the Fisher Scientific A-200DS and is the answer not in the manual?

Fisher Scientific A-200DS Specifications

General IconGeneral
BrandFisher Scientific
ModelA-200DS
CategoryScales
LanguageEnglish

Summary

Technical Specifications

Model and Common Features

Details specifications for A-Series models, common features, and electrical requirements.

Preparation and Installation

Work Area Selection Criteria

Guidelines for choosing a suitable environment, considering drafts, vibrations, and temperature.

Step-by-Step Installation

Procedures for setting up the balance: leveling, connecting power, and warm-up.

User Interface and Settings

Keyboard Operation

Describes the balance keyboard layout and the function of each key.

Basic Operations

Performing Basic Weighing

Step-by-step guide for performing a basic weighing operation.

Taring (Zeroing) Procedures

Instructions on how to tare the balance to zero for weighing samples in containers.

Calibration Procedures

Automatic Calibration

Instructions for using the balance's internal weight for automatic calibration.

External Calibration

Lists permissible external calibration weights and procedures.

Advanced Calibration

Calibrating with External Weights

Step-by-step guide for calibrating the balance using an external weight.

Modifying Calibration Variance

Procedure for adjusting calibration values to compensate for differences with known weights.

Dual Range Operation

Balance Configuration

Set Up Menu Navigation

Overview of Set Up menus for configuring display and print options.

Display and Print Settings

Details options within the Set Up-Display and Set Up-Print menus.

Display and Zeroing Configuration

Beeper and Range Configuration

Print Configuration

Data Transmission Settings

Interface Applications

I/O Communication

RS-232C Serial Transfer

Information on RS-232C serial communication, baud rates, and cable length.

Data Handling

Print and Baud Commands

Data Transmission Commands

Troubleshooting Guide

Error Displays and Causes

Identifies common error messages (OVER, UNDER, U, NO CAL) and their potential causes.

Troubleshooting Remedies

Provides recommended solutions for common balance error messages.

Initialization and Correction

Balance Initialization

Procedure for resetting the balance to default parameters and erasing user data.

Linearity Correction

Procedure for performing linearity correction using test weights.

Related product manuals