Heater Installation Tips
The filter pump in box manual may include items such as a pool inlet adapter, air jet valve, pool inlet jet nozzle, and
strainer grid. These items do not fit our inlet outlet ports, and are not included for that reason. These are examples of
heater systems you can use with your iPool:
To run the heater the first time, please ensure that the heater light stays on, and the filter pump is set to Continuous.
Initially, the heater may need up to 12 hours to heat up your iPool when it is filled with tap water, which is normally
around 50 degrees. It will heat the pool gradually, starting at one degree an hour. Please note this may take longer in
outdoor conditions
If your heater light does not turn on even though there is electricity please do the following:
1. Change the filter cartridge and replace with a brand new one (not washed).
2. Flood the filter pump chamber to clear it out any residual air inside of it.
3. Check the hoses for any air bubbles inside of them. You may need to flush out the hoses and shake them several times
to clear out the bubbles.
If this does not work you need to adjust the heater pressure switch setting from 3 to 1. This is referred to in your heater
manual on page 5 on your manual.
Here is a video showing how to remedy the filter pump:
Intex 2500 GPH Krystal Clear Pool Filter Pump Instructional Video | 633T
THE IPOOL INSTRUCTION MANUAL
Troubleshooting
Please carefuy read is instruction manual
before instaing and using e iPl
33