- 4 -
INSTALLATION:
The installation of this heater for use with No.1, No.2, Diesel or Kerosene and
shall conform with local codes or, in the absence of codes, with the National Fuel
Gas Code ANSI Z223.1/NFPA 54. Installation of the unit shall be in accordance
with the regulations of the authorities having jurisdiction or the CSA Standard
B139.
CLEARANCE TO COMBUSTIBLES:
TOP FRONT SIDES REAR FLUE PIPE
3 ft 10 ft 3 ft 3 ft 3 ft
FUEL: This heater will operate with No.1, No.2, Diesel or Kerosene.
Note: No.1 Fuel Oil or Kerosene must be used for
temperatures less than –10º C (8º F).
REMOTE TANK OPTION:
The FVO-400RC may be installed with a remote fuel tank providing the
manufacturer approved FVO-TLS remote fuel kit is used. This kit includes the tiger
loop system using a single line supply and pressure relief valve. This system
prevents overpressure fuel supply and stops the fuel flow in the case of a leak in
the fuel line where pump vacuum pressure is lost. A maximum of 50 ft supply
hose must be used with this installation.
All installations must conform to local installation codes and authorities having
Jurisdiction.
ELECTRICAL: WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding)
plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle.
115v supply must be available. Please note that the heater
requires 15 amps for proper operation. Ensure appropriate
gauge extension cord is used.
• 12/3 AWG at 50 Feet
• 10/3 AWG at 100 Feet