- 13 -
Determine the nozzle you
would like to use and insert
it into the spray gun or spray
wand by pulling back on
the quick-connect tting.
Once the nozzle is in place,
push the collar back to its
original position. General
ow rates for each nozzle
can be found on page 16.
4
Turn the pump on by
rotating the variable-
pressure dial clockwise
to the desired position.
Reference ow rate and
spraying pressure chart on
Page 16.
5
To begin spraying, simply
hold down the trigger on the
spray gun.
Priming your sprayer
NOTE: Although rare, when spraying for the rst time or after storing
the sprayer for an extended amount of time, the sprayer may need help
priming. If the sprayer turns on and you can hear the pump running, but
no liquid is passing through the sprayer, you will need to manually prime
the sprayer according to the steps below:
1. With the sprayer off, remove the battery and make
sure the battery cover is shut.
2. Remove the tank lid and take the tank strainer out to
reveal the inside of your sprayer tank.
3. Locate the inlet lter at the bottom of the sprayer tank
(See diagram 3 on page 15 for a visual representation).
Gently wiggle the inlet lter until it comes apart from
the pump connection. Set aside.
4. Using a garden hose or similar delivery method,
rapidly run clean water into the connection where the
inlet lter was.
5. Reinstall the inlet lter with the mesh screen facing
the bottom of the tank, ll the sprayer with some
water, and insert a charged battery. Test the sprayer
by activating the spray trigger.