1735
Getting Started
30
Flexi set I ranges: 15 A / 150 A / 3000 A RMS (non-distorted sine wave)
Resolution: 0.01 A
For ranges 150 A/3000 A
Intrinsic error:
±(0.5 % of m. v. + 10 digit)
Operating error:
±(1 % of m. v. + 10 digit)
For range 15 A
Intrinsic error:
±(0.5 % of m. v. + 20 digit)
Operating error:
±(1 % of m. v. + 20 digit)
The errors of the current probes are not considered.
By using Flexi-Set:
Flexi Set measuring
error:
±(2 % of m. v. + 10 digit)
Position influence:
±(3 % of m. v. + 10 digit)
CF (typical): 2.83
Note
Error for current clamps is specified separately.
Power Measurement (P, S, D)
• Measuring range: see V RMS and A RMS measurement
• Power errors are calculated by adding the errors of voltage and current
• Additional error due to power factor PF
• Specified error x (1-IPFI)
• Maximum Range with Voltage range 830 V delta-connection and 3000 A
current range is 2.490 MW
Intrinsic error:
±(0.7 % of m.v. +15 digit)
Resolution: 1 kW
Operating error:
±(1.5 % of m.v. + 20 digit)
Typical range with Voltage range 230 V Wye connection and 150 A Current range is
34.50 KW
Intrinsic error:
±(0.7 % of m.v. +15 digit)
Resolution: 1 W to 10 W
Operating error:
±(1.5 % of m.v. + 20 digit)
The errors of the current sensors themselves have not been considered.